Top mounted magnetic flip level gauge

Detail:                

   ZK-UZ-C-F series side mounted type magnetic turning column liquid level meter is on-site installation of direct reading liquid level meter and variable transmission unit using high quality stainless steel material, promulgated by the Ministry of chemical industry of magnetic level gauge standard HG/T21584 manufacturing; while providing PTFE lining magnetic turning column liquid level meter, level meter connecting part of the liquid material with PTFE, widely used in all kinds of petrochemical, chemical companies, measurement of any type, any of the concentration of acid, alkali and strong oxidizing agents such as process medium level. The standard 4-20mA current signal is converted into a standard by the circuit.
Is suitable for low temperature to high temperature, vacuum to high pressure and other environment, is the ideal liquid level measurement products in the petroleum, chemical and other industrial sectors. Depending on the location of the vessel, the side and top two forms are provided. According to different working medium, while providing stainless steel and ABS, PP-R engineering plastics three kinds of material, including ABS, PP-R material is also suitable for acid, alkali and other corrosive media.
The characteristics of
To float for the measuring element, driving magnetic turning column display, without energy.
With the upper and lower limit switch output, can realize remote alarm, limit control.
With the transmitter can realize the liquid level far distance indicator, detection and control.
The main technical indicators
Installation form content
Side mounted type
Top mounted
Installation spacing (range)
Stainless steel
500~5000 (mm)
500~2500 (mm)
PP-R, ABS
500~4000 (mm)
Working pressure
0.6,1.6,2.5,4.0MPa
0.6,1.6,2.5MPa
Medium density
>0.6g/cm3
>0.76g/cm3
Connecting flange
Stainless steel
(PN1.0-4.0 20-40) (DN20) (GB9119-88)
(PN1.6 200-25) (DN200) (GB9119-88)
ABS
(PN1.0 20-10) (DN20) (GB9119-88)
(PN0.6 200-6) (DN200) (GB9119-88)
Subject material
1Cr18Ni9Ti, ABS, PP-R (working pressure 0.6MPa)
Medium temperature
-40~100 (PP-R:-40~80, ABS)
Ambient temperature
-40~+70
Indication error
+ 10mm
Medium viscosity
1st (10-4m2/s)
Upper and lower limit switch output
1, control sensitivity: 10mm
2, output contact capacity: 2A AC220V
3, contact life: 5 x 104 times
4, explosion-proof features: ia II CT4 nature of the security
Electric transmission, continuous display
1, accuracy: 1.5%
2, output load: 750
3, output signal: 0~10mA output, AC 220V power supply
4~20mA output, DC 24V
4, explosion-proof features: ia II CT4 nature of the security
The components and wiring system
1, upper and lower limit switch output
The switch and the converter are composed of a self retaining tongue spring switch and the switch are respectively arranged in the field and the control room, provided by the converter three to the contact switch.
2, the electric remote
The two parts of the measurement unit and the variable delivery unit.
3, explosion-proof
A with explosion-proof, upper, lower limit switch output
The explosion-proof switch is composed of a reed switch and a relay contact, which can provide a pair of normally open or normally closed contacts. Such as users need more contact can be a special design order.
With the explosion of the remote type security B
Suitable for use in class II electrical equipment (plant), C grade gas, the highest surface temperature group T4 (135).
C usage notes
1 the transmitter housing is provided with an external grounding, and the user must be reliably grounded.
2 the application of the safety gate shall comply with the use of the description content.
3 transmitter and safety barrier of intrinsically safe end connection cable for two conductor shielded cable, wire cross-sectional area >0.5mm2, cable allows distributed capacitance is 0.8 f.
The user owned flange
Installation form
Main body material
Nominal diameter
Nominal pressure
D
D1
D2
N
D
F
B
Side loading
Stainless steel
20
4.0MPa
105
75
56
4
14
2
16
ABS
20
1.0MPa
105
75
56
4
14
2
16
Top loading
Stainless steel
200
2.5MPa
360
310
274
12
26
3
32
ABS

¡¾close¡¿